Nirmaanpro

Tools › User guides › Building Frame Designer

How to use the Building Frame Designer

The Building Frame Designer analyses your whole house as a 3D RCC frame (like STAAD) and designs every beam, column, slab, footing and staircase to IS 456, IS 13920, IS 1893 and IS 875. This guide explains every box on the page, step by step, and how to read the results.

Open the Building Frame Designer › Quick start

Quick start (5 minutes)

  1. In Units for your inputs, choose Metres and millimetres or Feet and inches.
  2. Type the column grid spacings in Spacings along X and Spacings along Y (e.g. 12'6", 10, 11'3" or 4, 3.5, 4) and press Update grid.
  3. Use the Columns and Beams tools on the plan to remove columns or beams that are not in your house. Use Walls to set 230 / 115 mm / no wall on each beam, and Stairs to place the staircase.
  4. Go to 2 Building: number of storeys, floor heights, concrete and steel grade, starting member sizes.
  5. Go to 3 Loads: live loads, floor finish, SBC of soil, earthquake zone and wind speed.
  6. Press Analyse & design. Everything appears under 4 Results — free to view on screen.
Your inputs are saved in your browser automatically, so you can close the page and continue later on the same device. Changing any input shows a yellow bar: press Analyse & design again to refresh the results.

Step 1 — Plan

Grid

FieldWhat to enterTypical valueTip
Units for your inputsMetres and millimetres, or Feet and inches.—Only the inputs change. Results, drawings and the report are always in m and mm (IS 456 practice). Switching does not change your design.
Spacings along X (left → right)Centre-to-centre distances between column lines, left to right, separated by commas.3 – 5 m (10 – 16 ft)In feet you can type 12'6" or 12.5. Up to 10 bays. Lines are numbered 1, 2, 3 …
Spacings along Y (top → bottom)Same, from top to bottom of the plan.3 – 5 mLines are lettered A, B, C … from the top.
Update gridPress after changing spacings.—If the number of bays changes, columns and beams are reset to every grid point and openings, walls and stairs are cleared.

Plan tools

ToolHow to useTypicalTip
ColumnsTap a grid point to add or remove a column.—Every beam must reach a column through the beam network, otherwise you get a warning.
BeamsTap a grid line between two points to add or remove a beam.—Beams are the same on every floor and on the plinth. A slab forms in every bay closed by beams on all four sides.
Slab openingsTap a bay to leave it without a slab (duct, courtyard, lift).—For a staircase use the Stairs tool instead — it designs the stair too.
WallsTap a beam to change the wall on it: 230 → 115 → no wall.Outer 230, inner 115Roof beams carry only the parapet.
StairsTap a bay to place a staircase; tap it again to change it.—See the stair settings below.
Columns at every grid point / Beams on every grid lineQuick buttons to fill the whole grid.—Useful after changing the grid.

Stair settings (box under the plan)

FieldWhat to enterTypical valueTip
TypeDog-legged (2 flights), Straight flight, or Open-well (3 flights).Dog-legged for housesA straight flight needs a long bay (about 4.5–5 m for a 3 m storey).
Flights go alongX (along grid 1, 2, 3) or Y (along A, B, C).The longer side of the bayThe arrow on the plan shows the direction going up.
First flight starts fromWhich grid line the first flight starts at.—Flips the stair.
Riser (max)Largest riser you accept.150 – 170 mm (6 – 6.5 in)NBC limit for houses is 190 mm. The tool divides the storey height into equal risers not above this.
TreadGoing of each step.250 – 300 mm (10 – 12 in)
Flight widthClear width of each flight. 0 = fit the bay.0.9 – 1.2 mUnder 0.9 m gives a warning (NBC minimum for houses).
Stair goes up to the roofTick if a mumty (stair cover room) is built on the roof.TickedAdds 115 mm walls 2.4 m high and a 120 mm roof slab over the stair.

The stair bay gets no floor slab. Its flights and landings are designed as waist slabs (IS 456 cl 33) with live load 3 kN/m² (IS 875 Part 2), and their load goes to the beams around the bay and, through a landing beam, to the columns.

Tracing your plan drawing

Under Your plan drawing (optional), upload a photo, scan or screenshot of your house plan (JPG or PNG; for a PDF take a screenshot first). It stays on your device and shows under the grid. Then:

  1. 1. Set scale — tap both ends of a length you know on the drawing (for example the overall length written on it) and type its real length, then Apply scale.
  2. 2. Mark columns — tap each column on the drawing. Columns in one line can be a little off; they are lined up automatically.
  3. 3. Make grid from columns — the grid spacings and columns are created for you (rounded to 5 cm or 1 inch). Beams are put on every grid line: remove any that are not there with the Beams tool.
FieldWhat to enterTypical valueTip
Image widthReal width of the picture.—Set by “Set scale”; you can also type it.
OpacityHow strongly the drawing shows.0.4 – 0.7
Shift right / Shift downMoves the picture under the grid.—Fine alignment after “Make grid”.
Fit image to grid / Remove imageQuick buttons.—

Plot boundary footings

If columns stand on the plot boundary, their footings cannot spread outside it. In the Plot boundary box choose each side that is on the boundary (Left = line 1, Right = last number, Top = line A, Bottom = last letter). The column face and the footing edge are kept flush with the boundary line.

ChoiceWhat happensNote
Not boundaryNormal isolated footing centred under the column.—
Strap footing (recommended)A strap beam at footing level ties the boundary footing to the next column inside. It carries the off-centre moment, so the soil pressure stays even. The tool designs the strap beam (size, steel, stirrups) and adds it to the BBS.Needs a column further in on the same grid line.
Eccentric footingNo strap. The column below the plinth and the plinth beams carry the moment P × e, so they need more steel.Plinth beams must be on.

Step 2 — Building

FieldWhat to enterTypical valueTip
Number of storeys above plinth1 (ground only) to 5 (G+4).2 (G+1)A height box appears for each storey.
Floor heightsFloor-to-floor height of each storey.3.0 m (10 ft)Ground-floor height is measured from the plinth. Allowed 2.4 – 6 m.
Plinth height above groundTop of plinth beam above ground level.0.45 – 0.6 m
Top of footing below groundDepth of the footing top below ground.1.2 – 1.5 mThe footing thickness is added below this.
Plinth beams (tie beams at plinth level)Tick to tie the columns at plinth level.TickedNeeded for soft soil and for eccentric boundary footings.
Concrete grade / steel gradeM20 – M30, Fe 415 / Fe 500.M25, Fe 500IS 456 Table 5: M25 minimum for moderate exposure.
ExposureMild or Moderate.ModerateSets the cover: 20 / 30 mm for beams and slabs.
Starting member sizesColumn, beam, plinth beam sizes and slab thickness.Column 300×300, beam 230×400, slab 125With auto-size on, failing members grow in 50 mm steps until they pass.
Auto-size membersTick to let the tool enlarge failing members.TickedUntick to check your own fixed sizes.

Step 3 — Loads

FieldWhat to enterTypical valueTip
Live load — floor / roofIS 875 Part 2.2.0 / 1.5 kN/m²Residential floors 2.0; accessible roof 1.5.
Floor finish — floor / roofTiles, screed, waterproofing.1.0 / 1.5 kN/m²
Masonry unit weightBrick masonry.19 – 20 kN/m³Fly-ash bricks / AAC blocks are lighter (AAC about 7).
Openings in wallsDoors and windows as % of wall area.15 – 25 %
Parapet height / thicknessRoof parapet.1.0 m / 115 mm
Safe bearing capacity of soilFrom the soil test report (Foundation section).100 – 200 kN/m²Use our SBC calculator if you have a borehole log.
Seismic zoneIS 1893 Part 1:2016 zone map.IIIMost of South Bengal is Zone III; North Bengal IV / V.
Soil typeI rock / hard, II medium, III soft.IISoft soil: no bearing increase under earthquake.
Importance factor1.0 residential, 1.2 more than 200 occupants, 1.5 important building.1.0
Frame typeSMRF (R = 5, ductile detailing to IS 13920) or OMRF (R = 3).SMRFZones III–V should use SMRF.
Masonry infill wallsTick if brick infill is built in the frame.TickedUses T = 0.09h/√d for the period.
Basic wind speed VbIS 875 Part 3 Annex A for your town.Kolkata 50 m/s
Terrain category1 open land … 4 dense city.2
Force coefficient CfWind force coefficient for the building.1.2

Step 4 — Results

After Analyse & design, the results show (all free on screen):

A row in red means a check still fails at the largest size tried: change the plan (shorter span, extra column) or the sizes, then run again.

Input sheet for RCC Estimator Pro

At the bottom of the results, open Input sheet for RCC Estimator Pro. It lists every input of RCC Estimator Pro in the same order as its form, with the value from your design. Rows marked “Input to be done separately” (doors, windows, bricks, plaster, tiles, rates…) are not worked out here. Where members differ, the most common size and steel are given.

PDF report (₹49 per design)

Everything is free to view. To print or save the complete design report (design basis, loads, every member, footings, stairs, BBS, quantities and the RCC Estimator input sheet) press Print / PDF report and pay ₹49 for that design. Keep the receipt code: it unlocks the same design on another device. Changing any input makes it a new design.

Questions people ask

Is the Building Frame Designer free?

Yes. All analysis, design, drawings and the bar bending schedule are free on screen. Only the printable PDF report costs ₹49 per design.

Can I enter my plan in feet and inches?

Yes. Choose “Feet and inches” in Units for your inputs. Grid spacings accept 12'6" or 12.5; member sizes are in inches. Results stay in metres and millimetres.

How do I design a column on the plot boundary?

In the Plot boundary box choose Strap footing (recommended) or Eccentric footing for that side. The footing is kept flush with the boundary and designed for the eccentric load.

Does it replace a structural engineer?

No. It is an engineering aid for regular RCC frames. Have the design checked and signed by a qualified engineer before construction.

‹ All user guides · All tools · Ask a question