The Building Load Analysis calculator works out dead and live loads (IS 875 Parts 1–2), wind (Part 3) and seismic base shear and storey forces (IS 1893, equivalent static method) for a building, and designs a typical slab, beam, column and footing to IS 456 under 1.5(DL + LL), with a summary schedule.

Open the Building Load Analysis ›

Premium — ₹49, one time. Open the tool and press unlock. You sign in with your email (a sign-in link, no password) and pay once; the calculator then stays unlocked on your account on any phone or computer where you sign in with the same email.

Quick start

  1. Unlock the tool (₹49).
  2. Fill sections 1–6: project, materials, sizes, dead, live, wind and seismic data.
  3. Fill the trial slab, beam, column and footing (7–10).
  4. Read the checks and the summary schedule; print or save as PDF.

1–2 · Project, materials and member sizes

FieldWhat to enterTypical valueTip
Project name, CityCity sets the basic wind speed.
Storeys above ground, floor height, plan L × B4, 3.0 m, 15 × 10 m
Concrete, steel, link grades; unit weight of RCCM25, Fe 500, Fe 415; 25 kN/m³
Safe bearing capacityFrom the soil report.
Slab thickness, beam b × D, column sizesTrial sizes.125; 230 × 450; 230 × 450
Covers — slab, beam, column, footing20 / 25 / 40 / 50 mm

3–4 · Dead and live load

FieldWhat to enterTypical valueTip
Floor finish thickness / unit weight50 mm, 24 kN/m³
Ceiling plaster thickness / unit weight12 mm, 20.4 kN/m³
Services allowance0.5 kN/m²
External / internal wall thickness, masonry unit weight, plaster230 / 115 mm, 20 kN/m³, 24 mm
Opening reduction factorWall area left after openings.0.85
Roof waterproofing2.0 kN/m²
Occupancy; corridor / balcony LLIS 875 Part 2.Residential; 3.0 kN/m²Column LL is reduced 10 % per floor carried, max 50 %.

5–6 · Wind and seismic

FieldWhat to enterTypical valueTip
k1, terrain, k3, k4, Kd, Ka, Kc, CfIS 875 Part 3:2015 factors.k1 1.0, terrain 2, 0.9, 0.9, 0.9, Cf 1.2
Seismic zone, importance I, R, soil type, building typeIS 1893 Part 1:2016.Zone III, I 1.0, R 5 (SMRF), soil II
Columns per floor, beam length, external / internal wall length per floorFor the seismic weight.25 % LL in the seismic weight when LL ≤ 3 kN/m²; roof LL not included.

7–10 · Slab, beam, column and footing

FieldWhat to enterTypical valueTip
Slab: lx, ly, panel case (Table 26), bar dia & spacing, basic span/depth, kt3.6 × 4.8 m; 26; kt 1.4
Beam: effective span, support condition, bars, stirrups4.8 m; 5 bars; 2-legged
Column: effective length factor k, tributary area, beam and wall load per floor, bars, tie pitchk 0.8; 16 m²
Footing: self-weight allowance, L × B, depth, bars10 %; 2 × 2 m; 500 mm

Results: loads, seismic base shear and storey forces, slab, beam, column and footing design checks and a summary schedule. Use Print / save as PDF. The members are designed for gravity 1.5(DL + LL) only — the lateral forces are worked out but not distributed to individual members (use the Building Frame Designer for that).

Questions people ask

Does it design members for earthquake forces?

It works out the base shear and storey forces, but designs the members for 1.5(DL + LL) only. For earthquake design of every member use the free Building Frame Designer.

Why is column live load reduced?

IS 875 Part 2 allows 10 % reduction per floor carried, up to 50 %, except where the live load exceeds 5 kN/m².