Water supply, water quality and treatment, sewerage and sewage treatment, stream pollution, air and noise pollution and solid waste management, following the CPHEEO manuals, IS 10500:2012, IS 2470, CPCB norms and the 2016 waste-management rules.
9.1 Water demand & population forecasting
Arithmetic increase method
Pn=P0+nxˉ
P0 = last known population; n = number of decades; x̄ = average increase per decade
r = average (geometric mean) percentage growth per decade; n = decades
Gives high values; suits young, fast-growing towns
Incremental increase method
Pn=P0+nxˉ+2n(n+1)yˉ
x̄ = average increase per decade; ȳ = average incremental increase (may be +ve or −ve)
Gives values between arithmetic and geometric methods
Logistic curve – saturation population
Ps=P0P2−P122P0P1P2−P12(P0+P2)
P0, P1, P2 = populations at three equally spaced times t0, t1, t2
S-shaped growth curve
Goodrich formula (peak demand)
p=180t−0.10
p = demand as % of annual average; t = period in days (1/24 to 365)
Gives 180% for a day, 148% for a week, 128% for a month
Fire demand (CPHEEO)
Q=100P
Q = fire demand in kL/day; P = population in thousands
Recommended for communities above 50,000
CPHEEO per capita supply for towns with piped supply but no sewerage is 70 lpcd.
CPHEEO per capita supply for cities with piped supply where sewerage exists or is planned is 135 lpcd.
CPHEEO per capita supply for metropolitan and mega cities with sewerage is 150 lpcd.
CPHEEO peak factor for water supply is 3.0 for population up to 50,000, 2.5 for 50,000–2 lakh and 2.0 above 2 lakh.
Design period recommended by CPHEEO is 30 years for distribution pipes, intake works and mains, and 15 years for treatment units, pumps and service reservoirs.
Rural water supply under the Jal Jeevan Mission is planned at 55 lpcd (earlier 40 lpcd).
9.2 Water quality & IS 10500:2012
Hardness from Ca and Mg
TH=Ca2+×2050+Mg2+×1250
TH = total hardness (mg/L as CaCO₃); Ca, Mg in mg/L; 50, 20, 12 = equivalent weights
Equivalent weight of CaCO₃ = 50
Carbonate & non-carbonate hardness
CH=min(TH,Alk),NCH=TH−CH
CH = carbonate (temporary) hardness; NCH = non-carbonate (permanent) hardness; Alk = total alkalinity as CaCO₃
IS 10500:2012 pH range for drinking water is 6.5–8.5 with no relaxation.
Nitrate: 45 mg/L with no relaxation; excess causes methaemoglobinaemia (blue-baby syndrome).
Free residual chlorine: minimum 0.2 mg/L, permissible up to 1 mg/L (IS 10500:2012).
Lead 0.01 mg/L, mercury 0.001 mg/L and cadmium 0.003 mg/L are limits with no relaxation.
Acceptable limit of arsenic in drinking water is 0.01 mg/L.
Total coliform and E. coli shall not be detectable in any 100 mL sample of drinking water.
New to these topics? Start with the Basic HandbookThe fundamentals of civil engineering explained simply — free to read online, then come back to the Advanced Handbook for exam-level formulas.
g = 9.81 m/s²; Gs = specific gravity of particle; d = diameter (m); ν = kinematic viscosity (m²/s)
Valid for laminar settling, Re < 1 (d up to about 0.1 mm)
Surface overflow rate
vo=AQ=BLQ
Q = flow (m³/d); A = plan area of tank (m²); B, L = width and length
Particles with vs ≥ vo are fully removed in an ideal tank
Removal of a slower particle (ideal tank)
r=vovs
r = fraction removed for particles with vs < vo
Detention time
td=QV
V = tank volume (m³); Q = flow (m³/h)
Velocity gradient (Camp)
G=μVP
P = power input (W); μ = dynamic viscosity (N·s/m²); V = volume (m³); G in s⁻¹
Removal efficiency of an ideal settling tank depends only on surface overflow rate, not on depth or detention time.
Discrete particle settling is Type I, flocculent settling Type II, zone (hindered) settling Type III and compression settling Type IV.
Flocculators are designed for G of about 10–75 s⁻¹ with Gt of about 10⁴–10⁵ and detention of about 10–40 minutes.
Optimum coagulant dose is found by the jar test.
Alum, Al₂(SO₄)₃·18H₂O, is the most common coagulant and works best in the pH range of about 6.5–8.5.
9.4 Filtration, disinfection & softening
Uniformity coefficient
Cu=D10D60
D60, D10 = sizes finer than which 60% and 10% (by mass) of the sand lies; D10 = effective size
Chick's law of disinfection
lnN0Nt=−kt
N0, Nt = organisms initially and after time t; k = rate constant
Slow sand filters work at about 100–200 L/h/m², while rapid sand filters work at about 3000–6000 L/h/m².
Effective size of sand for slow sand filters is about 0.2–0.3 mm.
Rapid sand filter media have an effective size of about 0.45–0.70 mm and a uniformity coefficient of about 1.3–1.7 (CPHEEO).
In a slow sand filter purification is mainly biological, by the 'schmutzdecke' layer on top of the sand; bacterial removal is about 98–99%.
Chlorine reacts with water to form hypochlorous acid (HOCl), which is about 80 times more effective than the hypochlorite ion (OCl⁻).
Break-point chlorination: beyond the break point, any added chlorine remains as free residual chlorine.
Minimum contact time for chlorine before supply is 30 minutes.
Fresh bleaching powder contains about 30–35% available chlorine (commonly taken as 33%), and it loses strength on storage.
In lime–soda softening, lime removes carbonate hardness and soda ash removes non-carbonate hardness.
Zeolite (base-exchange) softening can produce water of zero hardness; the bed is regenerated with brine (NaCl).
The Nalgonda technique for defluoridation uses alum, lime and bleaching powder.
9.5 Distribution systems & storage
Hazen–Williams formula (SI)
V=0.849CR0.63S0.54
V = velocity (m/s); C = Hazen–Williams coefficient; R = hydraulic radius (m); S = slope of energy line
Water hammer pressure rise (sudden closure)
Δp=ρcV
c = pressure-wave celerity (m/s); V = velocity destroyed (m/s)
Applies when closure time ≤ 2L/c
The dead-end (tree) system is cheap and simple but water stagnates at the dead ends.
The grid-iron system gives supply from more than one direction, so there are no dead ends and fewer shutdowns.
CPHEEO minimum residual pressure in distribution mains is 7 m for single-storey, 12 m for two-storey and 17 m for three-storey buildings.
Balancing storage of a service reservoir is found by the mass curve method or by the analytical (hourly demand) method.
The Hardy Cross method is used to analyse looped pipe networks.
9.6 Sewage quantity & sewer design
Babbitt peak factor
QavgQmax=P0.25
P = population in thousands
Rational method (storm runoff)
Q=360CIA
Q = peak runoff (m³/s); C = runoff coefficient; I = rainfall intensity (mm/h) for duration = tc; A = area (ha)
Manning's formula
V=n1R2/3S1/2
n = Manning's roughness; R = hydraulic radius (m); S = bed slope
R = D/4 for a circular sewer running full or half full
Self-cleansing velocity (Camp–Shields)
Vs=f8β(Gs−1)gd
β = sediment constant (≈0.04 to start motion, up to 0.8 for full cleansing); f = Darcy friction factor; Gs = specific gravity of particle; d = particle size
Sewage flow is commonly taken as 80% of the water supplied (CPHEEO).
CPHEEO (2013) sewage peak factor is 3.0 up to 20,000 population, 2.5 for 20,000–50,000, 2.25 for 50,000–7.5 lakh and 2.0 above 7.5 lakh.
Minimum velocity in sanitary sewers should be 0.6 m/s at present peak flow and 0.8 m/s at design (ultimate) peak flow (CPHEEO 2013).
Maximum velocity in sewers is generally limited to 3.0 m/s to prevent scouring.
Sanitary sewers are designed to run at most 0.8 full at ultimate peak flow (CPHEEO 2013).
Minimum diameter of a public sewer is 150 mm.
Manning's n for concrete sewers is commonly taken as 0.013.
A circular sewer running half full has the same velocity as when running full but half the discharge.
In a circular sewer the maximum velocity occurs at about 0.81 depth and the maximum discharge at about 0.94 depth.
9.7 BOD, COD, DO & stream pollution
BOD exerted in t days (base e)
BODt=L0(1−e−kt)
L0 = ultimate first-stage BOD; k = rate constant (base e, per day)
BOD exerted in t days (base 10)
BODt=L0(1−10−KDt)
KD = rate constant (base 10)
k = 2.303 KD
Temperature correction of BOD rate
kT=k20θT−20
T = temperature (°C); θ ≈ 1.047
BOD by dilution method
BOD=PD1−D2
D1, D2 = DO of diluted sample initially and after incubation (mg/L); P = decimal fraction of sample in the mix
SWM Rules 2016 require segregation at source into three streams: biodegradable (wet), non-biodegradable (dry) and domestic hazardous waste.
Under SWM Rules 2016, non-recyclable waste with calorific value of 1500 kcal/kg or more shall not be landfilled but used for energy recovery or co-processing.
Landfill composite liner (SWM Rules 2016): 1.5 mm HDPE geomembrane over 90 cm compacted clay with permeability not more than 10⁻⁷ cm/s.
Optimum C/N ratio for composting is about 25–30.
Under the Plastic Waste Management Rules, plastic carry bags must be at least 120 µm thick (from 31 December 2022).
Bio-Medical Waste Rules 2016 colour coding: yellow for anatomical waste, red for contaminated recyclable plastics, white puncture-proof containers for sharps and blue for glassware.
Test yourself on this chapterFree 20-question mini mock tests with answers and explanations, and a new question every day.
New to these topics? Start with the Basic HandbookThe fundamentals of civil engineering explained simply — free to read online, then come back to the Advanced Handbook for exam-level formulas.
Values follow the current Indian Standards and IRC / Indian Railways documents named in each item. Always check the latest amendment of a code before using a value in design.